BUEIA – "Spark Advance Retard Configuration"

TypeBits
Offset366 (0x016e)
Size1 Byte

Description:

Spark advance and fuel reduction configuration

Bitfields:

Bit-No.Meaning
0Activate on accel
1Activate on WOT transition
2Activate only if accel and WOT
3Use initial values
4Deactivate when leaving WOT
5Deactivate when no accel
6Enable ramp out
7Stop accel enrichment when activated

Note:
For variables that have a scaling factor and/or a translational offset given, use this formula to calculate the output value:
output_value = (EEPROM_value * scale) + translate


Please double-check all information from this site before using them!