Type | Table |
---|---|
Offset | 436 (0x01b4) |
Size | 16 Bytes |
Element Size | 2 Bytes |
Elements | 8 |
Columns | 2 |
Rows | rows |
Data Scale | 0.025000 |
Data Translate | 0.000000 |
Data Units | Degrees |
Axis Scale | 0.010000 |
Axis Translate | -40.000000 |
Axis Units | Degrees C |
Description:
Idle Spark Advance
The spark advance (data) against engine temperature (axis) in idle condition. For DDFI-2 and early DDFI-3 (BUEOD ... BUEZD): The interpolated value is added to the value of the timing table. For later DDFI-3: The interpolated value can be used instead of the Timing Table, depending on the settings of the Spark Advance Configuration byte. This is a self-contained table, alternating between the axis value in the even and the data value in the odd positions.
Note:
For variables that have a scaling factor and/or a translational offset given, use this formula to calculate the output value:
output_value = (EEPROM_value * scale) + translate
Please double-check all information from this site before using them!