BUE1D – "Fan Duty Cycle Map"

TypeMap
Offset796 (0x031c)
Size16 Bytes
Element Size1 Byte
Elements16
Columns4
Rowsrows
Scale1.000000
Translate0.000000
UnitsPercent
X-AxisFan Duty Cycle Map Battery Axis
Y-AxisFan Duty Cycle Map Temperature Axis

Description:

Fan duty cycle map for battery and engine temperature

Cooling fan duty cycle map as a function of battery voltage and engine temperature.

Note:
For variables that have a scaling factor and/or a translational offset given, use this formula to calculate the output value:
output_value = (EEPROM_value * scale) + translate