| Type | Value |
|---|---|
| Offset | 80 (0x0050) |
| Size | 1 Byte |
| Scale | 0.100000 |
| Translate | 0.000000 |
| Units | Deg./10ms |
Description:
Change in throttle movement indicationg a full acceleration condition
Full acceleration condition exists, if the difference (current throttle - avg. throttle) is larger than this value. If the full accel condition is set to a value greater than 127, then full accel is disabled and only light acceleration is active. If the full accel condition is set to a value less or equal than 127, then the same amount of fuel is injected simultaneously on both injectors.
Note:
For variables that have a scaling factor and/or a translational offset given, use this formula to calculate the output value:
output_value = (EEPROM_value * scale) + translate
Please double-check all information from this site before using them!