BUEKA – "Battery Voltage Correction"

TypeTable
Offset232 (0x00e8)
Size24 Bytes
Element Size2 Bytes
Elements12
Columns2
Rowsrows
Data Scale0.001333
Data Translate0.000000
Data UnitsMilliseconds
Axis Scale0.010000
Axis Translate0.000000
Axis UnitsVolts

Description:

Battery voltage correction

The battery voltage correction (data) against battery voltage (axis). The injector pulsewidth is extended to correct for slow injector opening with lower battery voltage. This is a self-contained table, alternating between the axis value in the even and the data value in the odd positions.

Note:
For variables that have a scaling factor and/or a translational offset given, use this formula to calculate the output value:
output_value = (EEPROM_value * scale) + translate


Please double-check all information from this site before using them!