Type | Bits |
---|---|
Offset | 408 (0x0198) |
Size | 1 Byte |
Description:
Fuel closed loop setup
Bitfields:
Bit-No. | Meaning |
---|---|
0 | Independent front cylinder closed loop enable |
1 | (reserved) |
2 | (reserved) |
3 | (reserved) |
4 | (reserved) |
5 | (reserved) |
6 | Log Front O2, AFV and EGO Corr. in place of Bat Corr., WUE and IAT Corr. (not recommended) |
7 | Master enable for closed loop |
Note:
For variables that have a scaling factor and/or a translational offset given, use this formula to calculate the output value:
output_value = (EEPROM_value * scale) + translate
Please double-check all information from this site before using them!