BUE3D – "Full Acceleration Condition"

TypeValue
Offset80 (0x0050)
Size1 Byte
Scale0.100000
Translate0.000000
UnitsDeg./10ms

Description:

Change in throttle movement indicationg a full acceleration condition

Full acceleration condition exists, if the difference (current throttle - avg. throttle) is larger than this value. If the full accel condition is set to a value greater than 127, then full accel is disabled and only light acceleration is active. If the full accel condition is set to a value less or equal than 127, then the same amount of fuel is injected simultaneously on both injectors.

Note:
For variables that have a scaling factor and/or a translational offset given, use this formula to calculate the output value:
output_value = (EEPROM_value * scale) + translate


Please double-check all information from this site before using them!