BUEOD – "Throttle Position Sensor Moving Average Fraction"

TypeValue
Offset24 (0x0018)
Size1 Byte
Scale1.000000
Translate0.000000
Units

Description:

TPS fraction used to detect TP changes

The throttle position filter value to detect throttle acceleration. The filtered throttle position (moving average) is calculate using the following formula: 'TP_filter(n) = TP_filter(n-1) + (TP_current - TP_filter(n-1) * filter/64' Valid range of filter value is 1 ... 64.

Note:
For variables that have a scaling factor and/or a translational offset given, use this formula to calculate the output value:
output_value = (EEPROM_value * scale) + translate


Please double-check all information from this site before using them!