BUEIB – "Throttle Position Sensor Reset Voltage"

TypeValue
Offset18 (0x0012)
Size2 Bytes
Scale0.010000
Translate0.000000
UnitsVolts

Description:

TPS voltage with a fully closed throttle, written on a TPS reset

The throttle position sensor voltage input to the ECM when the throttle plate (butterfly) is fully closed. This value will be written on a TPS reset.

Note:
For variables that have a scaling factor and/or a translational offset given, use this formula to calculate the output value:
output_value = (EEPROM_value * scale) + translate


Please double-check all information from this site before using them!