BUEIB – "Air Temperature Correction"

TypeTable
Offset186 (0x00ba)
Size14 Bytes
Element Size1 Byte
Elements14
Columns2
Rowsrows
Data Scale1.000000
Data Translate0.000000
Data UnitsPercent
Axis Scale1.000000
Axis Translate-40.000000
Axis UnitsDegrees C

Description:

Air Temp correction

The air temperature correction (data) against air temperature (axis). This correction covers air density changes due to temperature changes. This is a self-contained table, alternating between the axis value in the even and the data value in the odd positions.

Note:
For variables that have a scaling factor and/or a translational offset given, use this formula to calculate the output value:
output_value = (EEPROM_value * scale) + translate


Please double-check all information from this site before using them!