BUEIB – "Startup Fuel Pulsewidth"

TypeTable
Offset32 (0x0020)
Size6 Bytes
Element Size1 Byte
Elements6
Columns2
Rowsrows
Data Scale0.133000
Data Translate0.000000
Data UnitsMilliseconds
Axis Scale1.000000
Axis Translate0.000000
Axis UnitsTPS (8-bit)

Description:

Starting fuel pulse length

The startup fuel pulse duration (data) against throttle position (axis). This is a self-contained table, alternating between the axis value in the even and the data value in the odd positions.

Note:
For variables that have a scaling factor and/or a translational offset given, use this formula to calculate the output value:
output_value = (EEPROM_value * scale) + translate


Please double-check all information from this site before using them!