Type | Table |
---|---|
Offset | 308 (0x0134) |
Size | 14 Bytes |
Element Size | 1 Byte |
Elements | 14 |
Columns | 2 |
Rows | rows |
Data Scale | 1.000000 |
Data Translate | 0.000000 |
Data Units | Pressure (User d |
Axis Scale | 1.000000 |
Axis Translate | 0.000000 |
Axis Units | ADC Counts |
Description:
Air Box Pressure conversion
The airbox pressure (data) against airbox pressure sensor voltage (axis) expressed in A/D counts. The A/D counts must be in an ascending order and in the 0-255 range (8 bit resolution)covering 0-5 volts input voltage. Airbox pressure can be in any units, but has to be consistent between this and the other airbox pressure tables. This is a self-contained table, alternating between the axis value in the even and the data value in the odd positions.
Note:
For variables that have a scaling factor and/or a translational offset given, use this formula to calculate the output value:
output_value = (EEPROM_value * scale) + translate
Please double-check all information from this site before using them!