DDFI-3 – "Current Errors Byte 4"

TypeBitfield
Size1 Byte
Logged as"CDiag4"

Description:

Current trouble codes, byte 5

Bitfields:

Bit-No.Meaning
0AMC stuck open
1AMC stuck closed
2AMC short to ground
3AMC short to supply voltage
4AIC failure
5Sidestand input always low
6Sidestand input always high
7Sidestand failure

Note:
For variables that have a scaling factor and/or a translational offset given, use this formula to calculate the output value:
output_value = (raw_value * scale) + translate